<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-18 16-36-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 3/5, 72 dBuV SelectUK
Pilot RDS Phase Difference
6.6 kHz 72 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 4491 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,8 dBr 4,45 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SelectUK" C46F 15 (Other M) 1 0 1 5 16:35, 18.12.2025
RT
"On Air Now: The Selection - "
AF EON
94.4, 99.3, 105.7 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/18 16.35.14 Total samples: 4491 Equivalent time: 0:03:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 5,4 dBr MIN: 2,8 dBr AVE: 4,45 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/12/18 16.35.14) 16.22 16.24 16.26 16.28 16.30 16.32 16.34 0 2 4 6 Pm [dBr]